Specifi cations
Model Numbers Keypads:

HQRA-W1B-XX,         1-button keypad
HQRA-W2BS-XX,       2-button keypad
HQRA-W3BS-XX,       3-button keypad
HQRA-W4BS-XX,       4-button keypad
HQRA-W5B-XX,         5-button keypad
HQRA-W6B-XX,         6-button keypad
HQRA-W7B-XX,         7-button keypad

HQRA-W1RLD-XX,     3-button top group & 2-button bottom with raise/lower
HQRA-W2RLD-XX,     two 2-button groups, each with raise/lower
HQRA-W3BD-XX       two 3-button groups

HQRA-W3BSRL-XX,    3-button with raise/lower keypad
HQRA-W4S-XX,         4-button with raise/lower keypad
HQRA-W5BRL-XX,      5-button with raise/lower keypad
HQRA-W6BRL-XX,      6-button with raise/lower keypad

Power 120 V 50 / 60 Hz 0.5 A

Typical Power Consumption0.6 W
Test conditions: all backlights on medium-intensity, two LEDs on (two presets active), keypad powered at 120 V
Regulatory Approvals UL, CSA, NOM, FCC, IC, COFETEL
Environment Ambient operating temperature: 32 °F to 104 °F (0 °C to 40 °C), 0% to 90% humidity, non-condensing. Indoor use only.
Communications HomeWorks® QS RF seeTouch® Architectural keypads communicate with the system through Radio Frequency (RF) and must be located within 30 ft (9 m) of a repeater.
ESD Protection Tested to withstand electrostatic discharge without damage or memory loss, in accordance with IEC 61000-4-2.
Surge Protection Tested to withstand surge voltages without damage or loss of operation, in accordance with IEEE C62.41-1991 Recommended Practice on Surge Voltages in Low-Voltage AC Power Circuits.
Power Failure Power failure memory: should power be interrupted, the keypad will return to its previous state when power is restored.
Mounting Requires a U.S.A. wallbox. 3 ½ in (89 mm) deep recommended, 2 ¼ in (57 mm) deep minimum.
Wiring HomeWorks® QS RF seeTouch® architectural keypads require a 120 Vhot and neutral wire connection.